          | Model | DS1062CA | DS1102CA | DS1202CA | DS1302CA |  
          | Bandwidth | 60MHz | 100MHz | 200MHz | 300MHz |  
          | Real-time Sample Rate | 400 MSa/s, 2 GSa/s (Logic Analyzer) |  
          | Equivalent Sample Rate | 50 GSa/s |  
          | refresh rate | 2000 wfms/s |  
          | Memory Depth | 10 kpts (Single Channel), 5 kpts (Dual Channel) |  Advanced Features 
      
        
          | 1. The 2 GSa/s maximum real-time sample rate, the 50 GSa/s maximum equivalent time sample rate |  
          | and up to 300 MHz of bandwidth ensures you capture and observe your entire signal. |  
          | 2. Up to 2000 wfms/s refresh rate |  
          | 3. Ultra Compact Design with small footprint save your bench space |  
          | 4. 5.7¡¦ 64K TFT color LCD, bright and vivid waveform display |  
          | 5. Memory depth: 10 kpts (Single Channel), 5 kpts (Dual Channels) |  
          | 6. Versatile trigger modes: Edge, Video, Pulse Width, Slope, Alternate |  
          | 7. Adjustable trigger sensitivity: Effectively filter noise from trigger signal and avoid false trigger |  
          | 8. 20 automatic measurements |  
          | 9. Cursor measurements: Manual, Track and Auto Measure modes |  
          | 10. 10 waveforms, 10 setups, BMP and CSV storage |  
          | 11. Math functions: Add, Subtract, Multiply, FFT, Invert |  
          | 12. Special digital filter and waveform recorder |  
          | 13. Built-in hardware frequency counters |  
          | 14. Dual channels plus external trigger. Bandwidth including 60 MHz, 100 MHz, 200 MHz, 300 MHz |  
          | 15. Standard interface: USB Device, RS-232¡FUSB Host, to support USB disk and USB printer |  
          | 16. Standard configuration: Pass/Fail test,the signal out of the pass fail function is isolated |  
          | to prevent unwanted interference |  
          | 17. Multi-language user interface, built-in help system |  | 
  
    | 
      
        
          | Model | DS1062CA | DS1102CA | DS1202CA | DS1302CA |  
          | Bandwidth | 60 MHz | 100 MHz | 200 MHz | 300 MHz |  
          | Memory Depth | 10 kpts (Single Channel), 5 kpts (Dual Channel) |  
          | Channels | Dual Channels + External Trigger |  
          | Real-time Sample Rate | 2 GSa/s(Single Channel), 1 GSa/s (DUal Channel) |  
          | Equivalent Sample Rate | 50 GSa/s |  
          | Rise Time | 5.8 ns | 3.5 ns | 1.7 ns | 1.2 ns |  
          | Time Base Range | 5 ns/div to 50 s/div | 2 ns/div to 50 s/div | 1 ns/div to 50 s/div |  
          | Input Impedance | 1 M£[ || 15 pF | 1 M£[ || 15 pF¡A50 £[ |  
          | X-Y Operation | Bandwidth | 60 MHz | 100 MHz | 200 MHz | 300 MHz |  
          | Phase Difference | ¡Ó 3¢X |  
          | Trigger Modes | Edge, Video, Pulse Width, Slope, Alternative |  
          | Trigger Sources | CH1¡ACH2¡AExt¡AExt/5¡AAC Line |  
        
          
            | Common Parameters |  
            | Vertical Sensitivity | 2 mV/div to 10 V/div |  
            | Vertical Resolution | 8 bits |  
            | Input Coupling | DC, AC, Ground |  
            | Maximum Input Voltage | 300 V (DC + AC peak) |  
            | Roll Range | 500 ms/div to 50 s/div |  
            | Automatic Measurements | Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall time, Positive Width, Negative Width, Positive Duty Cycle, Negative Duty Cycle, Delay1¡÷2, Delay 1¡÷2 |  
            | Cursor Measurements | Manual, Track and Auto Measure modes |  
            | Math | Add, Subtract, Multiply, FFT, Invert |  
            | Storage | Internal¡G10 Waveforms and Setups |  
            | USB¡GBMP, CSV, Waveforms and Setups |  
            | I/O | USB Device¡AUSB Host¡ARS-232¡AP/F Out (Isolated) |  
            | Display | TFT (64K, Color LCD), 320 x 234 |  
            | Power | Worldwide Use, 100 ¡V 240 V / 50 VA Max |  
            | Weight | 2.3 kg |  |