Type 1700 Telephone Analyzer

Main Functions
Can test the electrical characteristics of an analogue corded and cordless phone, PBX and the transformer :
The tested items varies according to different country standard, Like : Frequency Response and Loudness Rating of the receiving、sending and Sidetone, Harmonic Distortion, Return Loss, DCR, Loop Current, DC I-V, I-R, ON-HOOK Leakage Current, ON HOOK AC Impedance Curve , OFF HOOK AC Impedance Curve, Linearity or Amplitude response , Clipping Test , the Sensitivity and Frequency Response Curve of the H.A.C. Magnetic Field … etc.
Catalogue | Main Features | Test Items | Accredited | Example of Test Screen
|       
           The fundamental combination of Type 1700  |       
      |||
|       
           Item  |       
              
           Model No.  |       
              
           Description  |       
              
           Usage  |       
      
|       
           1.  |       
            
            
         170 A  |       
            
         Telephone Analyzer  |       
            
         Mainframe. To control and process the input、output signal.  |        
      
|        
           2.  |        
               
           Monitor &Keyboard  |        
               
           High Resolution Color Display Monitor & Keyboard  |        
               
           Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax.  |        
      
|        
           3.  |        
               
           147B  |        
               
           Test Head  |        
               
           Sets the test angle and position of the artificial ear and mouth, to test the acoustic characteristics of the handset.  |        
      
|        
           4.  |        
               
           140M  |        
               
           Artificial Mouth  |        
               
           Generates a flat and stable、precise sound field, for testing the “Transmitter".  |        
      
|        
           5.  |        
             
           142EA-S or 142EK-S  |        
               
           Artificial Ear ( 142EA = IEC - 318 ; 142EK-S = 6 c.c. Coupler )  |        
               
           Receives the sound generated from the receive.  |        
      
|        
           6.  |        
               
           173 XXX (or 163 XXX)  |        
               
           Artificial Line ( 173 XXX ) or Terminator ( 163 XXX )  |        
               
           The artificial line in accordance to the specified country standard from the Telecom to the client ‘s site. ( Country Standard press here )  |        
      
|        
           7.  |        
              
           Hearing Protection & R. Noise Measurement Set  |       
              
           Combine for use with the Model-170A mainframe , to test the characteristic for the hearing protection and receiving residual noise of the telephone. ( See " Note " please )  |        
      |
|        
           9.  |        
               
           X-Y Mouse  |        
               
           Mouse  |        
               
           Replace the upward, downward, leftward, rightward and enter keys on the keyboard.  |        
      
|        
           10.  |        
               
           HP Printer ( Option)  |        
               
           Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.)  |        
               
           Print out the tested results & data.  |        
      
|        
           Note : GM-2 is used for testing the hearing protection and receiving residual noise , Some countries like Germany, England, Australia and New Zealand etc. required this kind of testing, If not require the testing for the hearing protection and receiving residual noise , then, GM-2 is not needed.  |        
      |||
Functions and Specifications of Type 1700
Feeding Bridge Voltage:
Symmetric Balanced Type. Voltage can be set from 5∼73V ±( 0.4﹪rdg + 0.15﹪FS )
Resolution: 0.1V, program-mable Software Setting.
Current : 0∼120 ma.
Accuracy: 0∼2 ma±(2.5﹪+ 2ua);Resolution 1ua; 2∼120 ma ± ( 1.5﹪+0.1 ma ).
Resistance:Rtot=RL1+RL2+Rv        
; 
RL1=RL2=150Ω=Resistance of the Inductor; Rv= Resistance of the programmable Serial Resistor ;
Rv = 0∼2550Ω (overall from 300Ω∼ 2850Ω, 10Ω / Step) .
Coupling capacitor:2u×2 , 4u×2 , 37u×2 , programmable and set automatically according to specific standard. (see Note 3).
Sweep frequency range:
In the range between 100 Hz∼10 KHz. The working range is deter-mined according to specific standard automati- cally, e.g.:180 Hz∼5 KHz according to Taiwan, EIA or China Std., or 160 Hz∼8 KHz according to BS6317 .
Resolution or interval of sweep frequencies: ( user selectable ) Fast:1/12 oct. Slow: 1/48 oct. ( ≒ continuous ) .
Test standard:ITU-T       
(CCITT)、EIA       
(IEEE)、OREM        
A、OREM       
B
Frequency response judgement : Mask ( Best Fit ) or 1KHz Normalization method. Automatically set According to specific standard.
Dynamic range of freq. response meas. : 70 dB.
Sending test range:+10 ∼ -60 dBV
Receiving test range:50 ∼ 120 dB SPL
Sidetone test range:50 ∼ 120 dB SPL
Sound level from Artificial Mouth : 75∼ 107dB SPL @ MRP. Set by the Software in step 0.1dB.
Artificial Line : 0∼ 7.5 Km, 0.5 Km / Step ; or 0∼ 15 Kft , 1 Kft / Step ( EIA ).
Electrical signal for receiving test:EMF =0.07V ∼3V, set by the software in step 0.1dB, accuracy <± (0.1 dB+1mv).
        
Test range of RE or LR:
| EIA | CCITT | OREM A / B | 
| TOLR: -20 ∼ - 65 dB | SLR: -15∼+ 30 dB | TRE:-20 ∼+ 25 dB | 
| ROLR: +30∼+75 dB | RLR: -20∼+ 25 dB | RRE:-15 ∼+ 30 dB | 
| SOLR: -20 ∼+25 dB | STMR:-10∼+ 35 dB | SRE:-25 ∼+ 20 dB | 
Tighten or Loosen of Upper / Lower limits range:-9.9∼+ 9.9 dB, 0.1dB/step.
Return Loss Measurement:
Terminal Impedance:Internal : 600Ω, 900Ω, and 3 different complex impedance according to UK, China and Germany standards.
External        
: Three additional   
Zext        
terminals are provided.Test range: 0∼      
40 dB ( Note:>        
        
40 dB is meaningless ),
Accuracy        
:
Frequency range:Determined by specific std. ranging from 100 Hz∼ 10 KHz .
Printer interface : HP or compatible.
Power:90V∼240V, 47∼63Hz, 150VA max..
Weight & dimension:        
N.W      
:( H )×(       
W )×( D )
MODEL-170      
:9.5  Kgs.      
17 ×      
36 ×      
39  CM
14"  MONITOR      
:11.5       
Kgs. 37      
× 35      
× 39      
CM
MODEL-147 :6.5 Kgs. 49 × 21 × 30 CM ( Test Head )
Optional Functions :
Type 1700 can test the PBX 、 PABX、Modem、 Receiver、 Transmitter、 ECM 、Transformer for Communication:
(a) With an optional Model-172A , when combined with Type 1700, can test various characteristics of PBX、
PABX、Modem, including the Insertion Loss、 Cross Talk (-40 ∼ -110dB)、Distortion、Return Loss、
           
Impedance、Frequency      
        Response、      
I-V Curves、       
I-R Curves, High Test Speed.
(b) With an optional Model-167 , when combined with Type 1700, can test the Receiver、Transmitter、Frequency
Response of ECM、Impedance、Distortortion、Sensitivity、H.A.C. Magnetic Field of Receiver, High Test
             
speed.
(c) With an optional Model-174 , when combined with Type 1700, can test the Frequency Response、Distortion、
Insertion Loss、Return Loss of theTransformer for Communication, also, user can test the above-mentioned various
characteristics under the condition of DC current setting from 0 to 120 mA, High Test Speed.